General Instructions
Mounting:
TheR-199requiresaminimumof1.75verticalinchesofspaceinastandard19”wideEIA
equipmentrack.Slidetheunitintotherackframeandsecureit,usingthe3000R/22Mmount-
inghardwaresuppliedwiththeunit.
Connections:
1.Connecttheaudiosignalstoscrewterminalsofthesameswitchgroup,ensuringthattheleft
andrightchannelsforthedefaultaudioareconnectedtotheLNC+and-,andthe
RNC+and-,andthesignalsforthealternatesignalareattachedtothe
LNO+and-andtheRNO+and-connectors.TheLOUT+and-andtheROUT
+and-areroutedtothemodulator,orotherdestination,oftheaudiosignals.
ConnecttheVideo(orRF/IF)signalstothesameswitchgroupastheiraudiosignals.The
default(orprimary)signalisconnectedtotheNC‘F’connector,andthesecondarysignalis
connectedtotheNO‘F’connector.Thecabletothemodulator(orcombiner,etc.)iscon-
nectedtotheCOMF’connector.
2. Connectthe+12VDClead(white)fromthepowersupplytothe+12vterminalontherear
panel,andtheblackleadtotheGNDterminal.Plugthepowersupplyintoa90-240VAC
poweroutlet,andtheunitisreadytofunction.Either+12Vterminalmaybeused.
3. Toactuatearelaysectionwithacontactclosure,connectthecontactsbetweeneachrelay
controlinputscrewterminals(SW1–SW4)andground(GND)screwterminal.Refertothe
rearpanelconnectionsillustrationandtheapplicationssectionofthismanual.
4.ToactuatearelayviaEthernetcontrol,entertheURL(IPaddress)ofthedeviceintothe
addressbarofanybrowser,entertheSetup/Controlsection,selecttheControltab.Clicking
ontherelayledwilltoggletheswitchesonoroff.
5.Toprogramtheunitfortimedoperationviatheincludedtimer,entertheURLfortheunitand
refertotheprogramminginformationlaterinthemanual.
Operation:
WhenthecontactclosurefortheappropriateRelayUnitisclosed,theoutput(Com)connection
isswitchedfromthedefaultinput(NC)tothealternateinput(NO).
Activationofanyofthe4relaysectionsmaybeaccomplishedbyexternalcontactclosure,
opencollectortransistor,webbrownserorlogicsignal.Themostusefulapplicationforcontrol-
lingtheR-199areprogrammedtimecontrol.
Theusershouldrealizethatthecontactclosureinput,ifitispulledtogroundtoswitchtosec-
ondary,willsupersedetheethernetcontrolinputsiftheyaresettoprimary.
Butifthecontactclosureinputsaresettoprimary,theethernetcontrolinputsmayswitchto
secondary.